COMPARISON AND DESIGN OF WATER TANK REST ON GROUND BY LSM AND WSM – A REVIEW (20150340)
Authors :
R.N.MULANI, V.S.PATIL,
, M.A.PATIL, P.G.MASTUD
, V.N.PARDE, P.R.UKIRADE, PROF.CHOUDHARIV.A.
Abstracts : In the new version of the IS 3370-2009
Code of Practice for concrete structures for the
storage of liquids that has adopted the widely used
limit state method. According to the provisions of
the previous version of the Code (IS 3370-1965),
design of water tanks is only allowed by the work
effort method. The study was conducted to compare
the design provisions of IS 3370 (1965) and IS 3370
(2009). In this study, a comparison of water design
reservoirs using Stress Limiting Worker methods is
performed. In order to carry out the comparative
design of the study, the three types of water tanks
set up a circular reservoir with a capacity of 500 kl,
an elevated square reservoir of the tank with a
capacity of 250 kl and a rectangle of groundwater
250 kl of its capacity. The quantities of materials
were calculated for each problem. The results are
presented as graphs and tables and noted that the
state water tank design method is more economical
since the amount of material required is less
compared to the work effort method.